Product Introduction
CS2350 bipotentiostat has two sets of built-in independent potentiostat /galvanostat. Experiments can be conducted simultaneously in each channel. Besides this, the two channels can jointly complete experiment of two-working electrode system such as RRDE and HDT. CS2350 bipotentiostat is the real double-channel potentiostat. It uses Ethernet connection. The customer can choose to use only one channel or both channels during experiment. EIS module is included in one channel.
Application
(1) Electrosynthesis, electrodeposition (electroplating), anodic oxidation, electrolysis
(2) Oxygen reduction reaction (ORR), oxygen evolution reaction (OER), Hydrogen evolution reaction (HER), carbon dioxide reduction.
(3) Energy and materials (Li-ion battery, solar cell, fuel cell, supercapacitor), advanced function materials, and sensor.
(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.


Standard supply
Instrument CS2350 x1
CS studio software x1
Power cable x1
Ethernet cable x1
Cell cable x 4
Dummy cell (1kΩ||100µF) x2


After-sales Service (**All the after service is FREE)
1. Warranty period: 5 years.
2. Provide installation guide, manual, software installation video, and training videos.
3. Lifetime free software upgrading of the same model and technical service.
4. Free repair service


Typical applications

Rotating ring-disk electrode (RRDE)
Oxidation/reduction reaction (ORR) study: while measuring the polarization curve of disk electrode in the main channel, apply a constant polarization potential on the ring electrode, and thus detect the intermediate products on the disk electrode. RRDE test becomes the typical method for ORR study.
 
Hydrogen diffusion test (HDT)
CS2350 Bipotentiostats are combined with H-cells. By measuring current of cathode hydrogen charging (the left cell) and hydrogen atoms anode oxidation (the right cell), it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.
Technical advantages

1. Impedance (EIS)
CS350 potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.).
EIS of AA6063 Al alloy in Ce3+ containing 3% NaCl solution
2. Polarization curve
Tafel plot can be obtained. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to obtain material’s pitting potential and protection potential and uate the its susceptibility to intergranular corrosion. The software uses non-linear fitting to analyze polarization curve, and can make fast evaluation of material’s anti-corrosion ability and inhibitors.
Polarization curve of Ti-based amorphous alloy & stainless steel in 3%NaCl solution
3. Voltammetry
Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), SCV, SWV, DPV, NPV,ACV, Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.
  
          
                                                                                                   
 LSV: mesoporous carbon material in 0.1M KOH               CV of PPy supercapacitor in 0.5 mol/L H2SO4
4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.
5. Full floating measurement
Full-floating mode be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)

6. Software development kit (SDK)
  We are able to provide API functions and development examples, which facilitates some users’ requirements for secondary development and self-defined measurements. We can provide .dll file.


Software Features
Cyclic voltammetry:
CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves. In CV technique, during the data analysis, there is function of selecting exact cycle(s) to show. You can choose to see a cycle or some cycles as you want. You can also export data or vector graph of an exact cycle or several cycles.

Tafel plot and corrosion rate:
CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.

 
Battery Test and analysis: 
charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy.

EIS analysis: Bode, Nyquist, Mott-Schottky plot
During EIS data analysis, there is built-in fitting function to draw the custom equivalent circuit.

Real time saving of data: The data can be automatically saved even in case of sudden power off.

Combination test: it can facilitate the automation of experiments and save time. With the unique function of combination test, you can choose several techniques, and set the wait time, the start time, and the cycles. Choose the experiments you want to run. Then you can make auto measurement of the set experiments as you want without having to wait in the lab. This function is especially useful if you have multi experiments to run and save your time greatly.

 

Data open: You can open the data files by txt format in notepad. Data can also be opened in Origin
Specifications
Specifications
Support 2-, 3- or 4-electrode systemInterface: Ethernet
Potential control range: Primary Channel: ±10V second Channel: ±10VCurrent control range: ±2A
Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz), 3μV (<10Hz)Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
Maximum current output: ±2ACV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHzLow-pass filters: Covering 8-decade
Potential and current range: AutomaticWeight / Measurements: 8kg,36.5 x 30.5 x16cm
 Operating System: Windows 2000/NT/XP/ win7/win8/win10
Electrochemical Impedance Spectroscopy (EIS)
Signal generator
Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
DC Bias:-10~+10VOutput impedance:50Ω
Waveform: sine wave, triangular wave and square waveWave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time:minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10VCurrent compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting
Techniques
Software -Techniques/Methods of CS2350
Channel 1

Stable polarization
  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)
  • Sweep-Step Functions (SSF)
Transient Polarization
  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)
Chrono Method
  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)
Voltammetry
  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV)
  • Square Wave Voltammetry (SWV)
  • Differential Pulse Voltammetry (DPV)
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV)
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)
Amperometric
  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)
Stripping Voltammetry
  • Potentiostatic Stripping
  • Linear Stripping
  • Staircase Stripping
  • Square Wave Stripping
  • Differential Pulse Voltammetry Stripping
  • Normal Pulse Voltammetry Stripping
  • Differential Normal Pulse Voltammetry Stripping
Electrochemical Impedance Spectroscopy (EIS)
  • EIS vs Frequency (IMP)
  • EIS vs Time (IMPT)
  • EIS vs Potential (IMPE)(Mott-Schottky)
Corrosion Measurements
  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)
Battery test
  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging
  • Potentiostatic Intermittent Titration Technique
  • Galvanostatic Intermittent Titration Technique
Extensions
  • Data Logger
  • Electrochemical Stripping/ Deposition
  • Bulk Eletrolysis with Coulometry (BE)
  • Rs Measurement
Channel 2
Stable polarization
  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)
  • Sweep-Step Functions (SSF)
Transient Polarization
  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)
Voltammetry
  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
Corrosion Measurements
  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)
Battery test
  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging
  • Potentiostatic Intermittent Titration Technique
  • Galvanostatic Intermittent Titration Technique
Extensions
  • Data Logger
  • Electrochemical Stripping/ Deposition
  • Bulk Eletrolysis with Coulometry (BE)
  • Rs Measurement

상품 정보 고시

제품소재 상품페이지 참고
색상 상품페이지 참고
치수 상품페이지 참고
제조자 상품페이지 참고
세탁방법 및 취급시 주의사항 상품페이지 참고
제조연월 상품페이지 참고
품질보증기준 상품페이지 참고
A/S 책임자와 전화번호 상품페이지 참고

사용후기

등록된 사용후기

사용후기가 없습니다.

상품문의

등록된 상품문의

상품문의가 없습니다.

배송정보

배송 안내 입력전입니다.

교환/반품

교환/반품 안내 입력전입니다.

관련상품

등록된 상품이 없습니다.

Customer

Customer Center

032-341-4265

월~금 : AM 9:00 ~ PM 18:00
토요일, 일요일, 공휴일은 휴무

Fax : 032-341-4266
E-Mail: yykwon@egtechnology.co.kr

공지사항
  • 게시물이 없습니다.

우리가 공급하는 제품의 회사입니다 (로고를 클릭 하시면 더 많은 정보를 얻을 수 있습니다)

상호명 : ㈜이지테크에이유 대표 : 권영열 사업자 등록번호 : 686-88-00063 이메일 : yykwon@egtechnology.co.kr
주소 : 경기도 부천시 소사로 160번길 101, 601호 (소사본동, 벨라루체II) 대표전화 : 032-341-4265 FAX : 032-341-4266
통신판매업 신고번호 : 제2017-경기부천-1862호

Copyright © 이지테크에이유. All Rights Reserved.